Alarmzentrale, 220vac, 8 zonen, sicherheitssystem, sicherheitstechnik, alarmanlage, alarmierungsanlagen, sicherheit, überwachungssystem, alarmsystem

Währungen : 

Alarmzentrale, 220vac, 8 zonen, sicherheitssystem, sicherheitstechnik, alarmanlage, alarmierungsanlagen, sicherheit, überwachungssystem, alarmsystem


Référence : C8Z
à partir de 72,00€ HT
Degressiv tarife durch quantität
Quantität HT
1 90,00€
10 81,00€
20 72,00€
 

Lagerabbau
Eigenschaften :

Dimension 225x260x80mm . Weight 1,5Kg . Supply 220Vac . Charger 12V/250mA


zusätzliche Informationen


Stock Verfügbar sofort


Siehe Packungsbeilage(fr)


TITLE_INFO_COMPL_CE_DOC


TITLE_INFO_COMPL_CE_PDF


Ecopart : 1,00€

The control panel is the core of the control system. All the peripherals are joined up to it: detector, contacts, signallings, etc. It provides the power supply of the whole installation even if there is a power failure thanks to a built-in battery. The panel controls 24hr/24hr the whole installation and cables included to prevent any attempt of sabotage. In case of alarm, it will activate the siren, the telephone transmitter, the paralysing gas cartridge, etc. It also manages all the time lapse relays: the delay that is necessary to activate the alarm and get out without the siren activating itself (exit delay), the delay that is necessary to enter and desactivate the alarm (enter delay) and the duration of it. Many models of control panels exist. They are mainly differentiated by the number of zones corresponding to the quantity of peripherals that the panel will be able to manage. It is always important to foresee 1 to 2 supplementary zones to keep the ability of developping the installation. The C8Z has 8 zones, 6 alarm + 1 panic + 1 anti tamper. Its special feature is a remote, lighted keypad with two security codes (ref.C8ZC not included), which can be installed behind the front door for example (the panic function is also on the keypad). Additional C7ZC keypads can be added (maximum 6) in order to ease access to a building with more than one entrance. Arming is quick and silent and there is intelligent automatic activation. Passage test on all zones with chimes zones. Output protected for interior and exterior sirens. Separate panic and 24hr function. Recall of last 250 triggerings. 8 events alarm . Non volatile memory. Programmable installer code. Separate controls for entrance time delay, exit time delay and alarm. Secure data transmission. Partial or complete activation function. We recommend this control panel for installations with 4 or 6 volumetrics (2 double technology detectors + 5 PIRs + 1 smoke detector for example).


  • Français
  • Anglais
  • Espagnol
  • Allemand
  • Italien